Class: SSS 3
Term: First Term
Subject: Basic Electricity
Time: 2 Hours 30 Minutes
Total Marks: 70
SECTION A: OBJECTIVES (40 Marks)
Instruction: Answer ALL 40 questions. Each question carries 1 mark.
- All of the following contribute to transformer losses EXCEPT ________. (a) eddy currents induced in conductive core material (b) resistive heating in windings (c) mechanical friction from a continuously rotating rotor inside a stationary transformer (d) hysteresis in the magnetic core
- A high-current connection in an electrical installation becomes abnormally hot while the load is within its rating. Which fault is most plausible? (a) An ideal zero-resistance connection (b) An excessively resistive or loose termination causing local heating (c) The multiplication of energy in a transformer (d) A change in voltage without any associated current or contact resistance
- An installation fault should NOT be investigated by ________. (a) touching exposed conductors to determine whether they are live (b) using a correctly rated testing instrument with proper precautions (c) checking appropriate records and circuit layout (d) isolating the relevant supply
- A metal-cased appliance develops an internal live-to-case fault. Why is protective earthing important? (a) It prevents all internal insulation damage from ever occurring (b) It provides a fault path that can help protective devices disconnect the supply (c) It makes the metal case an insulating material (d) It removes the need for any overcurrent device
- ________ is the physical principle by which a changing magnetic flux links a transformer secondary winding and induces an e.m.f. (a) Chemical dissociation (b) Frictional electrification (c) Mutual electromagnetic induction (d) Electrostatic repulsion
- The main reason for laminating a transformer core is ________. (a) To restrict circulating eddy currents and associated heating losses (b) To convert alternating current to direct current automatically (c) To eliminate all magnetic hysteresis without material selection (d) To prevent every form of copper loss in the windings
- An installation repeatedly trips after a new appliance is connected. Which fault-finding sequence is most appropriate? (a) Bypass the protective device during normal operation (b) Install a larger fuse automatically without checking conductors (c) Assume the trip itself proves the supply is defective (d) Isolate safely, inspect the relevant circuit and appliance, test, correct the cause, then verify
- Which of these is not an acceptable purpose of protective earthing? (a) To make contact with a live exposed conductor harmless in every circumstance (b) To support operation of appropriate fault protection (c) To reduce dangerous potential on exposed conductive parts (d) To connect suitable exposed metalwork to the protective conductor
- A protective device that melts its element when excessive current persists is a ________. (a) capacitor (b) rheostat (c) fuse (d) transformer
- Which claim about an ordinary transformer does NOT follow from electromagnetic induction? (a) It can change AC voltage levels through turns ratio (b) Its losses may heat the windings and core (c) It requires a time-varying flux to induce e.m.f. (d) It produces a sustained secondary voltage from steady direct current without switching
- ________ appliances rely on a protective earth connection for accessible metal parts that could become live in a fault. (a) Purely mechanical (b) Non-electrical (c) Class I (d) Class II double-insulated
- A newly installed socket has reversed polarity. Which approach is best before releasing it for use? (a) Increase connected load to verify the fault (b) Correct the wiring and complete appropriate verification tests with the supply isolated (c) Remove the protective conductor to balance polarity (d) Mark it for later repair and place it straight into service
- All these examples involve energy conversion EXCEPT ________. (a) a motor converting electrical energy to motion (b) a lamp producing light and heat from electrical input (c) an electric heater producing thermal energy (d) an instrument claiming to create electrical energy without input or source
- A technician has replaced a damaged protective conductor connection. What final action demonstrates good practice? (a) Assume all other connections are correct without testing (b) Increase fuse rating to mask future faults (c) Verify continuity and the relevant protection before returning the circuit to use (d) Remove the conductor again to reduce resistance
- A \(1.5\,\mathrm{kW}\) heater operates for 4 hours. The energy consumed is ________. (a) \(1.5\,\mathrm{kWh}\) (b) \(6\,\mathrm{kWh}\) (c) \(60\,\mathrm{kWh}\) (d) \(0.375\,\mathrm{kWh}\)
- Why should a circuit breaker be selected to suit the conductor and expected load? (a) A larger rating always makes a circuit safer (b) Trip ratings are selected only from the appliance’s colour (c) The breaker determines the energy source’s voltage independently (d) Its trip characteristics must protect the circuit without allowing unsafe overheating
- The correct step in responding to an overloaded, overheating transformer is to ________. (a) Add turns to the core while the unit remains energised (b) Reduce the load and investigate cooling, connections and rated capacity (c) Bypass the protective device to prevent interruptions (d) Cover ventilation openings to trap heat
- Which distinction between core loss and copper loss is correct? (a) Core loss is related to magnetic behaviour; copper loss arises mainly from winding resistance (b) Core loss occurs only as a result of secondary load current (c) Copper loss is independent of current in every operating condition (d) Core loss occurs only because of external tyres
- A transformer with correct turns ratio gives a lower output voltage under heavy load than under no load. Which explanation merits investigation? (a) A change in the output connector’s label (b) A guaranteed change in the number of turns during operation (c) A constant conversion of AC into DC by the core (d) Voltage drop associated with winding impedance and load current
- A device installed to provide a low-resistance connection of exposed metalwork to the protective system is associated with ________. (a) earthing (b) amplification (c) resonance (d) rectification
- Why is systematic fault location superior to replacing parts at random? (a) It avoids checking the repaired circuit (b) It connects test evidence with the probable cause and reduces unnecessary intervention (c) It proves every component is defective (d) It requires the circuit to remain energised throughout
- Which of these is not an appropriate conclusion from high transformer efficiency? (a) Operating load and conditions can affect efficiency (b) Output power is relatively close to input power (c) Some input power may still be dissipated as heat (d) The device has no losses and therefore requires no heat management
- Which feature characterises a Class II appliance? (a) A transformer efficiency above 100 per cent (b) Double or reinforced insulation rather than dependence on protective earthing for safety (c) Dependence only on a water-filled cooling unit (d) A compulsory exposed metal case with no insulation
- The principal reason to test the integrity of insulation before energising a repaired circuit is ________. (a) to reduce the risk of leakage, faults and dangerous contact during use (b) to increase electrical frequency automatically (c) to change a Class I appliance into Class II (d) to eliminate the need for continuity checks
- How does an RCD differ functionally from an ordinary overcurrent circuit breaker? (a) Both protect only against low supply voltage (b) An RCD replaces all earthing and fault analysis requirements (c) An RCD always measures power factor, never current (d) An RCD detects residual-current imbalance; an overcurrent breaker responds to overload or short circuit
- An ideal transformer has 800 primary turns and 200 secondary turns. A primary voltage of \(240\,\mathrm V\) is applied. The secondary voltage is ________. (a) \(60\,\mathrm V\) (b) \(960\,\mathrm V\) (c) \(240\,\mathrm V\) (d) \(120\,\mathrm V\)
- A motor converts electrical energy to mechanical output, while a generator converts ________. (a) electrical energy to electrical insulation (b) electrical energy to earthing resistance (c) mechanical energy to electrical energy (d) heat to unchanged chemical composition
- Which statement best contrasts open-circuit and short-circuit faults? (a) Both necessarily draw the same current (b) An open circuit interrupts the intended path; a short circuit creates an unintended low-resistance path (c) A short circuit is merely a different kind of insulation label (d) An open circuit always raises current above a short-circuit level
- Which of the following design changes most directly produces a step-up transformer when the supply voltage is unchanged? (a) Removing the laminated core and retaining the same turns (b) Increasing the wire colour contrast (c) Increasing the distance between the windings without changing turns (d) Increasing the ratio of secondary turns to primary turns
- A transformer delivering \(900\,\mathrm W\) from an input of \(1000\,\mathrm W\) operates at an efficiency of ________. (a) \(90\%\) (b) \(10\%\) (c) \(81\%\) (d) \(100\%\)
- Which of these is not an intended purpose of transformer cooling? (a) To dissipate heat generated by losses (b) To support reliable operation at the designed load (c) To create energy in excess of the transformer input (d) To keep insulating materials within temperature limits
- Why is the kilowatt-hour useful when comparing household appliance consumption? (a) It measures conductor cross-section directly (b) It expresses electrical energy used over time, not instantaneous power alone (c) It is the unit of electrical resistance (d) It describes the maximum frequency of a transformer
- An efficiency of \(92\%\) indicates that the output power is ________ of the input power. (a) \(0.92\) times (b) \(1.92\) times (c) \(9.2\) times (d) \(0.08\) times
- Which investigation best explains why a healthy lamp fails to light in one room while nearby circuits work? (a) Replace the utility meter without any evidence (b) Remove all earthing conductors before tracing (c) Assume all branch circuits must be shorted simultaneously (d) Trace supply continuity and examine the affected circuit using safe isolation and test procedures
- All these are typical design considerations for electrical protective devices EXCEPT ________. (a) coordination with circuit wiring (b) appropriate breaking capacity (c) the decorative colour of the appliance package as the decisive trip criterion (d) rated current and fault conditions
- Which assumption about an appliance class is NOT warranted? (a) Correct identification affects safety checks (b) A Class II label permits damaged insulation to be ignored (c) Class I equipment normally needs a protective earth (d) Manufacturers may state protective arrangements on a rating label
- ________ describes the transfer of energy between forms while the total energy is conserved. (a) Electrical earthing (b) Magnetic insulation (c) Energy conversion (d) Permanent energy creation
- An ideal transformer has \(V_p=230\,\mathrm V\) and \(N_p:N_s=10:1\). Which output is expected? (a) \(23\,\mathrm V\) (b) \(10\,\mathrm V\) (c) \(2300\,\mathrm V\) (d) \(230\,\mathrm V\)
- A transformer takes \(2.5\,\mathrm{kW}\) and supplies \(2.0\,\mathrm{kW}\). Its loss and efficiency are respectively ________. (a) \(2.0\,\mathrm{kW}\) and \(20\%\) (b) \(0.5\,\mathrm{kW}\) and \(125\%\) (c) \(4.5\,\mathrm{kW}\) and \(50\%\) (d) \(0.5\,\mathrm{kW}\) and \(80\%\)
- For an ideal transformer with \(N_p=500\), \(N_s=1000\) and \(V_p=110\,\mathrm V\), the secondary voltage is ________. (a) \(110\,\mathrm V\) (b) \(500\,\mathrm V\) (c) \(220\,\mathrm V\) (d) \(55\,\mathrm V\)
SECTION B: THEORY (30 Marks)
Instruction: Answer Question 1 and any other TWO questions. Each question carries 10 marks.
1. Answer the following questions.
(a) A transformer has 1,200 primary turns, 300 secondary turns and a 240 V primary supply. Calculate the ideal secondary voltage and show the turns-ratio relation. (5 marks)
(b) Explain five major sources of loss or temperature rise in transformers and appropriate means of limiting their effects. (5 marks)
2. Answer the following questions.
(a) A 2 kW appliance operates for 3.5 hours. Calculate its energy use in kilowatt-hours and joules. (5 marks)
(b) Analyse five ways electrical energy changes form in practical appliances or machines. (5 marks)
3. Answer the following questions.
(a) An installation has intermittent trips after rain. Describe five safe checks that could help locate the likely fault. (5 marks)
(b) Explain five reasons earthing and protective devices must be considered together in a safe installation. (5 marks)
4. Answer the following questions.
(a) Differentiate Class I and Class II appliances using five clear structural and safety considerations. (5 marks)
(b) Explain five fault-finding or maintenance actions a qualified technician should perform before an appliance is put back into service. (5 marks)
OBJECTIVE MARKING SCHEME
Question 1 – ✅ (c) mechanical friction from a continuously rotating rotor inside a stationary transformer
Question 2 – ✅ (b) An excessively resistive or loose termination causing local heating
Question 3 – ✅ (a) touching exposed conductors to determine whether they are live
Question 4 – ✅ (b) It provides a fault path that can help protective devices disconnect the supply
Question 5 – ✅ (c) Mutual electromagnetic induction
Question 6 – ✅ (a) To restrict circulating eddy currents and associated heating losses
Question 7 – ✅ (d) Isolate safely, inspect the relevant circuit and appliance, test, correct the cause, then verify
Question 8 – ✅ (a) To make contact with a live exposed conductor harmless in every circumstance
Question 9 – ✅ (c) fuse
Question 10 – ✅ (d) It produces a sustained secondary voltage from steady direct current without switching
Question 11 – ✅ (c) Class I
Question 12 – ✅ (b) Correct the wiring and complete appropriate verification tests with the supply isolated
Question 13 – ✅ (d) an instrument claiming to create electrical energy without input or source
Question 14 – ✅ (c) Verify continuity and the relevant protection before returning the circuit to use
Question 15 – ✅ (b) \(6\,\mathrm{kWh}\)
Question 16 – ✅ (d) Its trip characteristics must protect the circuit without allowing unsafe overheating
Question 17 – ✅ (b) Reduce the load and investigate cooling, connections and rated capacity
Question 18 – ✅ (a) Core loss is related to magnetic behaviour; copper loss arises mainly from winding resistance
Question 19 – ✅ (d) Voltage drop associated with winding impedance and load current
Question 20 – ✅ (a) earthing
Question 21 – ✅ (b) It connects test evidence with the probable cause and reduces unnecessary intervention
Question 22 – ✅ (d) The device has no losses and therefore requires no heat management
Question 23 – ✅ (b) Double or reinforced insulation rather than dependence on protective earthing for safety
Question 24 – ✅ (a) to reduce the risk of leakage, faults and dangerous contact during use
Question 25 – ✅ (d) An RCD detects residual-current imbalance; an overcurrent breaker responds to overload or short circuit
Question 26 – ✅ (a) \(60\,\mathrm V\)
Question 27 – ✅ (c) mechanical energy to electrical energy
Question 28 – ✅ (b) An open circuit interrupts the intended path; a short circuit creates an unintended low-resistance path
Question 29 – ✅ (d) Increasing the ratio of secondary turns to primary turns
Question 30 – ✅ (a) \(90\%\)
Question 31 – ✅ (c) To create energy in excess of the transformer input
Question 32 – ✅ (b) It expresses electrical energy used over time, not instantaneous power alone
Question 33 – ✅ (a) \(0.92\) times
Question 34 – ✅ (d) Trace supply continuity and examine the affected circuit using safe isolation and test procedures
Question 35 – ✅ (c) the decorative colour of the appliance package as the decisive trip criterion
Question 36 – ✅ (b) A Class II label permits damaged insulation to be ignored
Question 37 – ✅ (c) Energy conversion
Question 38 – ✅ (a) \(23\,\mathrm V\)
Question 39 – ✅ (d) \(0.5\,\mathrm{kW}\) and \(80\%\)
Question 40 – ✅ (c) \(220\,\mathrm V\)
THEORY MARKING SCHEME (Answer 3 × 10 = 30 Marks)
Question 1 (10 Marks)
(a) 5 marks: Relation Vs/Vp=Ns/Np (2), substitution (1), Vs=60 V (2).
(b) 5 marks: Copper I²R (1), hysteresis (1), eddy currents and lamination (1), load/ventilation (1), cooling/insulation condition (1).
Question 2 (10 Marks)
(a) 5 marks: E=Pt (1), 7 kWh (2), 1 kWh=3.6×10^6 J (1), 25.2 MJ (1).
(b) 5 marks: Five distinct valid examples: heater, lamp, motor, fan, sound device, generator etc., describing source/output energy; 1 each.
Question 3 (10 Marks)
(a) 5 marks: Isolate supply, inspect moisture ingress/insulation, test circuit and appliances, examine protective device, rectify cause and verify; five reasoned 1 each.
(b) 5 marks: Fault path, disconnection, conductor integrity, device rating, exposed metalwork and verification; any five 1 each.
Question 4 (10 Marks)
(a) 5 marks: Protective earth, double/reinforced insulation, accessible metal, markings, safety checks; 1 each.
(b) 5 marks: Isolation, fault diagnosis, suitable components, inspection, insulation/continuity tests, safe functional checks, documentation; any five 1 each.

Community Join the conversation Open discussion +