Class: SSS 3
Term: Second Term
Subject: GSM Maintenance And Repairs
Time: 2 Hours 30 Minutes
Total Marks: 70
SECTION A: OBJECTIVES (40 Marks)
Instruction: Answer ALL 40 questions. Each question carries 1 mark.
- The main reason hand tools should match the sizes and types of GSM fasteners is ________. (a) unsuitable tools can damage fasteners and nearby components during disassembly (b) larger screwdrivers always fit smaller fasteners safely (c) the highest torque should be applied before inspecting a screw (d) a mismatched tip improves access to delicate assemblies
- A workshop computer contains identifiable customer repair records. The most appropriate safeguarding measure is ________. (a) share all customer files on an unrestricted public computer (b) store records without device or customer references (c) retain private data permanently without access controls (d) restrict access and maintain records for legitimate service use
- A repair worker notices an exposed mains connection close to the test bench. Which action is most appropriate? (a) continue using the circuit with a lower-power charger (b) touch the conductors to check whether they are live (c) Stop affected work and arrange safe isolation and qualified correction (d) cover the connection with loose fabric and continue tests
- The ________ mode should be chosen to compare a measured potential difference with the manufacturer’s DC-voltage test points. (a) resistance (b) continuity (c) AC current (d) DC voltage
- A technician must compare analogue and digital meter readings on the same stable source. Which conclusion is sound? (a) Digital instruments are necessarily accurate regardless of setup (b) Both require correct connection, function and range selection; display method alone does not establish accuracy (c) Analogue meters do not require calibration or range selection (d) a negative digital reading always proves a defective source
- All these actions contribute to a well-equipped GSM repair bench EXCEPT ________. (a) keeping unnecessary combustible clutter beside heating equipment (b) keeping labelled part trays near the bench (c) providing suitable insulated hand tools (d) storing circuit diagrams for relevant handset models
- All these are meaningful workshop equipment categories EXCEPT ________. (a) an appropriate multimeter (b) unrelated promotional ornaments presented as essential diagnostic devices (c) suitable hardware opening tools (d) a relevant model-specific circuit diagram
- Which of the following arrangements best prevents small parts from different handsets being mixed? (a) Separate labelled trays linked to their job records (b) Keep screws from all phones in a single large tray (c) Place parts on a shared work surface without job labels (d) Identify parts only from memory at the end of the week
- The ________ of a workshop tool inventory should be based on the actual repair operations and safety needs. (a) brand popularity alone (b) preference for the largest and most expensive tool set (c) selection and quantity (d) advertising appearance of the equipment
- The first step before examining a board recently exposed to liquid should be to ________. (a) drive current through the board before diagnosis (b) test every connector at maximum voltage (c) expose the powered device to heat before identifying affected areas (d) avoid powering it, isolate energy sources and assess contamination safely
- Which of the following is the safest initial response before using a multimeter in resistance mode on a GSM circuit? (a) Disconnect the relevant power supply and check that the circuit is not energised (b) Use the resistance range while the charger remains connected (c) Connect the meter’s current socket directly across the battery (d) Assume the circuit is unpowered because the screen is dark
- The main reason to inspect a meter’s test leads before electrical diagnosis is to ________. (a) confirm the battery has a full charge (b) make the meter read the same number in every mode (c) identify damaged insulation or probes that could distort readings or expose the operator (d) decide the fault without checking the connection points
- A technician selects the resistance function on an energised handset board. The correct step is to ________. (a) increase the resistance range while leaving the board live (b) stop, disconnect power and recheck the measurement setup (c) bridge the probes directly across the battery (d) change sockets without verifying the test mode
- A digital meter on DC-voltage mode displays a minus sign before the reading. What is the most likely interpretation, assuming correct connections and range? (a) The probes have opposite polarity to the selected positive-reference direction (b) The power source has a negative output under all conditions (c) The circuit is necessarily shorted (d) The meter must be on the resistance range
- When checking a suspected short circuit, the appropriate first step is to ________. (a) continue charging while looking for a short (b) connect the current input across the handset battery (c) isolate the handset and use safe tests guided by known circuit information (d) touch adjacent pads with an uninsulated probe
- A workshop keeps only one unprotected copy of all technical diagrams and repair records. The most defensible improvement is ________. (a) maintain controlled backups and appropriate access to records (b) keep the only file on a shared flash drive (c) remove access restrictions to simplify retrieval (d) delete all service histories after an interruption
- A technician needs to lift a fragile plastic connector without damaging nearby contacts. Which tool selection is most reasonable? (a) A steel blade used to lever several contacts at once (b) An oversize screwdriver pushed beneath the clip (c) A suitable non-conductive opening tool used carefully (d) A heated soldering iron used on the plastic latch
- All of these measures support general workshop safety EXCEPT ________. (a) keeping a clearly marked first-aid point (b) securing electrical leads away from movement paths (c) inspecting damaged probe leads before use (d) working with liquids beside exposed powered electronics
- Which choice best integrates safety rules with equipment selection for a difficult GSM repair? (a) Select instruments by colour rather than function (b) Choose the appropriate schematic and instrument, isolate power as required, and document verified results (c) use resistance mode on energised points (d) replace components before considering the schematic
- A worker measuring DC voltage records inconsistent readings. What is the most appropriate next check? (a) Replace the battery immediately regardless of the test points (b) assume that the voltage is always stable when the display flickers (c) Verify the range, probe contact, reference point and meter condition (d) use a higher range without checking probe placement
- The principal reason to verify a circuit diagram against the actual handset model is ________. (a) revisions or different layouts may make a mismatched diagram misleading (b) schematics for all models are necessarily identical (c) only the brand logo determines internal wiring (d) hardware revisions can always be ignored during measurements
- The correct step when an unfamiliar board’s wiring cannot be matched confidently to the available diagram is to ________. (a) bridge unknown pads until the expected beep is heard (b) substitute an unrelated model diagram as definitive (c) pause intrusive work and obtain reliable model-specific information (d) replace components without comparing measured paths
- Why should a computer-based repair register include model, symptoms, test results and final work? (a) It guarantees that no customer dispute can occur (b) It means all devices with the same model must have the same fault (c) It removes the need for technical testing (d) It supports repeatable decisions, ownership traceability and accountability
- A computer is used to view a schematic while diagnosing a no-charge fault. Its principal technical role is to ________. (a) prove that a battery is physically undamaged (b) provide access to relevant stored technical information during systematic testing (c) replace all measurements with software guesses (d) identify a faulty component from appearance alone
- A circuit diagram identifies the intended route from a connector to a component. If continuity is absent in the unpowered route, the most defensible next action is ________. (a) apply power immediately to confirm the suspected break (b) replace the entire board without inspecting the route (c) short the connector pads to force a reading (d) inspect the relevant path and test points systematically for an interruption
- Which of the following would best distinguish the function of a circuit diagram from a physical photograph of a handset board? (a) The diagram always shows exact component colours and dimensions (b) A photograph documents all net connections more reliably than a schematic (c) The diagram represents intended electrical connections and component relationships symbolically (d) Both representations are interchangeable for every electrical test
- If the resistance measured across a circuit segment seems unexpectedly low, the best inference is ________. (a) The measured component is definitely an open circuit (b) A resistance reading alone uniquely identifies the defective chip (c) The path must be operating at its rated voltage (d) an alternate conductive path or component arrangement may affect the reading and requires further checking
- All these are proper uses of a multimeter EXCEPT ________. (a) measuring voltage with probes in the correct meter sockets (b) using the current input as a direct short across a battery’s terminals (c) checking unpowered continuity within the recommended range (d) checking test-lead integrity before use
- Which of the following is the strongest evidence that a diagnostic reading is trustworthy? (a) Appropriate test mode, sound leads, known reference points and reproducible measurement (b) A meter display that gives the same value in every mode (c) A reading obtained without a reference point (d) One unrepeatable number from a loose probe
- The ________ of an analogue multimeter should be observed from directly in front to reduce parallax error. (a) battery terminal labels (b) workshop entry log (c) printed brand logo (d) pointer and scale
- The principal reason for using a suitable antistatic work arrangement is ________. (a) ensure all circuits become electrically isolated without switching off (b) to limit damage from electrostatic discharge during electronic handling (c) allow bare hands to replace insulated tools (d) increase operating voltage through the board
- An analogue meter’s pointer appears displaced from its normal rest position before a test. What should the technician do? (a) Check appropriate zero adjustment and setup before interpreting measurements (b) Interpret the indicated value without examining the pointer (c) take the scale value from an extreme side angle (d) assume a zero error is irrelevant for all ranges
- ________ most directly reduces the chance of shorting adjacent board contacts during probing. (a) Broad metal tips pressed against several contacts (b) Fine, insulated probes used with controlled hand positioning (c) A bare wire loop held across neighbouring pads (d) The widest possible probe to improve contact
- ________ is a suitable tool for measuring a potential difference at specified circuit points. (a) A multimeter set to the correct voltage function (b) A continuity tester connected in series with the mains supply (c) A screwdriver touching both test points (d) An ohmmeter connected across a powered point
- Which practice does NOT conform to appropriate multimeter use? (a) checking the leads’ condition before testing (b) confirming the selected function against the connected sockets (c) choosing the correct reference point for the circuit (d) moving test leads between input sockets without checking the intended function
- ________ should be used to route electrical and equipment cables so that they do not obstruct safe movement in the workshop. (a) Unsecured leads across the walking area (b) Secure, orderly cable management (c) Open reels at the entrance to the bench (d) Test cables resting over hot equipment
- The correct step before reusing a screwdriver with a damaged handle is to ________. (a) continue using it if its tip still turns the screw (b) wrap the handle loosely with cloth (c) withdraw it from service until the tool is made safe or replaced (d) increase force to offset the damaged grip
- Which statement about a continuity beep is NOT reliable? (a) It can indicate low resistance on the tested path (b) It depends on meter thresholds and test conditions (c) It does not establish normal operation under load (d) It proves that the complete handset will work correctly under every operating condition
- The ________ on a technical diagram helps the technician match a symbol to a specific component or location. (a) workshop rental receipt (b) component designation or reference (c) customer’s phone number alone (d) technician’s lunch schedule
- The safest response to a swelling lithium-ion battery received at a GSM centre is ________. (a) puncture the casing to release pressure (b) reconnect power briefly to verify the battery can charge (c) avoid charging, heating or puncturing it and isolate it for appropriate handling (d) store it near active heating equipment for observation
SECTION B: THEORY (30 Marks)
Instruction: Answer Question 1 and any other TWO questions. Each question carries 10 marks.
1.
(a) Explain five safety precautions before using resistance or continuity mode on a GSM circuit. (5 marks)
(b) Compare five aspects of analogue and digital multimeter use, including their displays, ranges and errors. (5 marks)
2.
(a) Using a model-specific circuit diagram, outline five systematic tests for a handset that fails to charge. (5 marks)
(b) A DMM displays a negative voltage. Explain five checks needed before concluding that the circuit is faulty. (5 marks)
3.
(a) Describe five measures for organising workshop tools, small components and electronic repair records. (5 marks)
(b) A handset arrives with a visibly swollen lithium-ion battery. Evaluate five immediate safety actions. (5 marks)
4.
(a) Explain five conditions needed for a trustworthy continuity result on an unpowered GSM board. (5 marks)
(b) Differentiate an electrical circuit diagram from a photograph of a handset circuit board in five respects. (5 marks)
Objective Marking Scheme
Question 1 – ✅ (a) unsuitable tools can damage fasteners and nearby components during disassembly
Question 2 – ✅ (d) restrict access and maintain records for legitimate service use
Question 3 – ✅ (c) Stop affected work and arrange safe isolation and qualified correction
Question 4 – ✅ (d) DC voltage
Question 5 – ✅ (b) Both require correct connection, function and range selection; display method alone does not establish accuracy
Question 6 – ✅ (a) keeping unnecessary combustible clutter beside heating equipment
Question 7 – ✅ (b) unrelated promotional ornaments presented as essential diagnostic devices
Question 8 – ✅ (a) Separate labelled trays linked to their job records
Question 9 – ✅ (c) selection and quantity
Question 10 – ✅ (d) avoid powering it, isolate energy sources and assess contamination safely
Question 11 – ✅ (a) Disconnect the relevant power supply and check that the circuit is not energised
Question 12 – ✅ (c) identify damaged insulation or probes that could distort readings or expose the operator
Question 13 – ✅ (b) stop, disconnect power and recheck the measurement setup
Question 14 – ✅ (a) The probes have opposite polarity to the selected positive-reference direction
Question 15 – ✅ (c) isolate the handset and use safe tests guided by known circuit information
Question 16 – ✅ (a) maintain controlled backups and appropriate access to records
Question 17 – ✅ (c) A suitable non-conductive opening tool used carefully
Question 18 – ✅ (d) working with liquids beside exposed powered electronics
Question 19 – ✅ (b) Choose the appropriate schematic and instrument, isolate power as required, and document verified results
Question 20 – ✅ (c) Verify the range, probe contact, reference point and meter condition
Question 21 – ✅ (a) revisions or different layouts may make a mismatched diagram misleading
Question 22 – ✅ (c) pause intrusive work and obtain reliable model-specific information
Question 23 – ✅ (d) It supports repeatable decisions, ownership traceability and accountability
Question 24 – ✅ (b) provide access to relevant stored technical information during systematic testing
Question 25 – ✅ (d) inspect the relevant path and test points systematically for an interruption
Question 26 – ✅ (c) The diagram represents intended electrical connections and component relationships symbolically
Question 27 – ✅ (d) an alternate conductive path or component arrangement may affect the reading and requires further checking
Question 28 – ✅ (b) using the current input as a direct short across a battery’s terminals
Question 29 – ✅ (a) Appropriate test mode, sound leads, known reference points and reproducible measurement
Question 30 – ✅ (d) pointer and scale
Question 31 – ✅ (b) to limit damage from electrostatic discharge during electronic handling
Question 32 – ✅ (a) Check appropriate zero adjustment and setup before interpreting measurements
Question 33 – ✅ (b) Fine, insulated probes used with controlled hand positioning
Question 34 – ✅ (a) A multimeter set to the correct voltage function
Question 35 – ✅ (d) moving test leads between input sockets without checking the intended function
Question 36 – ✅ (b) Secure, orderly cable management
Question 37 – ✅ (c) withdraw it from service until the tool is made safe or replaced
Question 38 – ✅ (d) It proves that the complete handset will work correctly under every operating condition
Question 39 – ✅ (b) component designation or reference
Question 40 – ✅ (c) avoid charging, heating or puncturing it and isolate it for appropriate handling
Theory Marking Scheme
Question 1 (10 Marks)
(a) Disconnect power (1); verify de-energised state (1); inspect leads (1); choose function (1); touch appropriate test points safely (1).
(b) Analogue pointer/scale (1); digital display (1); correct range (1); polarity (1); parallax or zero/calibration (1).
Question 2 (10 Marks)
(a) Trace schematic path (1); verify model revision (1); make power safe (1); check connectors (1); test and document voltage/continuity (1).
(b) Select DC-voltage mode (1); proper leads/input sockets (1); polarity/reference (1); range and contact (1); repeat and compare (1).
Question 3 (10 Marks)
(a) Organised tools (1); separate labelled trays (1); model-specific diagrams (1); record backups (1); access controls (1).
(b) Do not charge (1); do not puncture (1); avoid heating (1); safely isolate (1); arrange proper handling/disposal (1).
Question 4 (10 Marks)
(a) Power isolated (1); sound leads (1); correct range (1); identified path (1); repeat check with cautious interpretation (1).
(b) Circuit diagram shows nets (1); photo shows layout (1); model revisions matter (1); designators show component reference (1); each has limitations (1).

Community Join the conversation Open discussion +